Intelligent split charging battery management
These units are designed for use with tail-lifts where it is required to simply cut the power to the control panel rather than to the motor. It monitors the voltage and when it reaches 10.8V (AVSG12B1) the built-in buzzer sounds for approximately 10 seconds, then this disconnects the control panel.
It will automatically reconnect when the voltage returns to 13V.
These units are designed for use with tail-lifts where it is required to simply cut the power to the control panel rather than to the motor. It monitors the voltage and when it reaches 21.7V (AVSG24B1) the built-in buzzer sounds for approximately 10 seconds, then this disconnects the control panel.
It will automatically reconnect when the voltage returns to 26V.
The Amber Valley Start Guard gives peace of mind to vehicle fleet operators. It safeguards the voltage in the starting battery by eliminating the possibility of a tail lift, passenger lift or double deck trailer lift, discharging the starting battery to a level where the vehicle is left stranded.
The Start Guard constantly monitors the battery voltage. If the voltage drops below a predetermined level (sufficient to start the engine) the unit will tell the operator by means of a buzzer or a real speech alarm that they must restart the engine. If they do not restart the engine, the unit will cut the power to the tail lift. When the engine is restarted, the power is automatically restored when the battery reaches a predetermined voltage.
AVSG12SG1 Technical Specification
| Cut-Off Voltage | Restart Voltage | Quiescent Current | Warning Current |
|---|---|---|---|
| 11.7V | 13.0V | 3.0mA | 2.5A |
| Delay To Warning | Warning Duration | Delay To Off From Warning | Warning Sound | 1 min | 7 secs | 55 secs | Buzzer |
AVSG24SG1 Technical Specification
| Cut-Off Voltage | Restart Voltage | Quiescent Current | Warning Current |
|---|---|---|---|
| 23.5V | 26.0V | 3.0mA | 2.5A |
| Delay To Warning | Warning Duration | Delay To Off From Warning | Warning Sound | 1 min | 7 secs | 55 secs | Buzzer |
The Amber Valley Start Guard gives peace of mind to vehicle fleet operators. It safeguards the voltage in the starting battery by eliminating the possibility of a tail lift, passenger lift or double deck trailer lift, discharging the starting battery to a level where the vehicle is left stranded.
The Start Guard constantly monitors the battery voltage. If the voltage drops below a predetermined level (sufficient to start the engine) the unit will tell the operator by means of a buzzer or a real speech alarm that they must restart the engine. If they do not restart the engine, the unit will cut the power to the tail lift. When the engine is restarted, the power is automatically restored when the battery reaches a predetermined voltage.
AVSG12SG2 Technical Specification
| Cut-Off Voltage | Restart Voltage | Quiescent Current | Warning Current |
|---|---|---|---|
| 11.7V | 13.0V | 3.0mA | 2.5A |
| Delay To Warning | Warning Duration | Delay To Off From Warning | Warning Sound | 1 min | 7 secs | 55 secs | Speech |
AVSG24SG2 Technical Specification
| Cut-Off Voltage | Restart Voltage | Quiescent Current | Warning Current |
|---|---|---|---|
| 23.5V | 26.0V | 3.0mA | 2.5A |
| Delay To Warning | Warning Duration | Delay To Off From Warning | Warning Sound | 1 min | 7 secs | 55 secs | Speech |